Can I put flue elbows straight on top of the boiler?
Elbows for offsetting can be fitted directly into the flue turret, or high level adapter on all our wall hung boiler variants. There is no requirement for running any straight flue length between them.
Please check our manual for total flue length allowance, as most extra 90 degree bends will result in either a 1500mm (Greenstar CDi Classic Range) or 2000mm (All other ranges) reduction and a 45 degree bend will lose 750mm (Greenstar CDi Classic Range) or 1000mm (All other ranges).
More Gas Boiler FAQs
- This is a test FAQ
- Is an external air break required when a condensate pipe is terminated into a rainwater downspout?
- How do I re-route a condensate pipe to reduce the external run?
- Where can I find the FD (serial) number on a Greenstar boiler?
- Can I fit your controls to an external oil boiler?
- Can I run boiler flues outside?
- Does an external condensate pipe have to be insulated?
- Which programmers are compatible with my gas boiler?
- Do I need a standoff kit to pipe up the back of your boilers?
- Why is the boiler blowing fuses?